Monado OpenXR Runtime
Loading...
Searching...
No Matches
xrt_imu_noise_calibration Struct Reference

IMU noise model and bias calibration, the noise density grows with the reading on each axis. More...

#include <xrt/xrt_tracking.h>

Collaboration diagram for xrt_imu_noise_calibration:

Data Fields

struct xrt_imu_sensor_calibration gyro
 Gyroscope calibration, in rad/s.
 
struct xrt_imu_sensor_calibration accel
 Accelerometer calibration, in m/s^2.
 
double accel_scale_random_walk
 Accelerometer scale random walk, in 1/sqrt(s).
 
double accel_scale_initial_sigma
 Standard deviation of the accelerometer scale before anything has been observed, unitless.
 

Detailed Description

IMU noise model and bias calibration, the noise density grows with the reading on each axis.

Note
This doesn't contain bias/scale itself, that should be applied by the drivers before sending to trackers.

Field Documentation

◆ accel

struct xrt_imu_sensor_calibration xrt_imu_noise_calibration::accel

Accelerometer calibration, in m/s^2.

Referenced by xrt::tracking::constellation::optimizer::propagateCovariance().

◆ accel_scale_initial_sigma

double xrt_imu_noise_calibration::accel_scale_initial_sigma

Standard deviation of the accelerometer scale before anything has been observed, unitless.

◆ accel_scale_random_walk

double xrt_imu_noise_calibration::accel_scale_random_walk

Accelerometer scale random walk, in 1/sqrt(s).

◆ gyro

struct xrt_imu_sensor_calibration xrt_imu_noise_calibration::gyro

Gyroscope calibration, in rad/s.

Referenced by xrt::tracking::constellation::optimizer::propagateCovariance().


The documentation for this struct was generated from the following file: